Small pressure tank see table 4 pg.
Franklin electric subdrive 300 fault codes.
Franklin electric subdrive utility.
Green motor frequency on display drive and motor are operating loose switch or cable connection incorrect motor or pump settings motor may be running backwards gulping water at pump inlet verify maximum frequency setting.
27 allows installation in small.
Franklin electric subdrive300 pdf user manuals.
Underload smart reset well recovery time.
It in compliance with national and local electrical codes and within franklin electric.
Rapid internal fault a fault was found internal to drive contact your franklin electric service personnel power down disconnect leads to the motor and power up the subdrive.
Power down disconnect leads to the motor and power up the subdrive.
Use of this unit with any other franklin electric motor or with motors from other manufacturers may result in dam age to both motor and electronics.
When used with the specified franklin electric motor see table 1 pg.
View online or download franklin electric subdrive300 installation manual.
Controller location selection controller location selection the subdrive controller is intended for operation in ambient temperatures up to 125 f 51 c at 230 vac input.
Subdrive 300 3 7 5 15 9 5050 17 8 5810 1 0 1 2 106 model pump hp kw motor hp kw.
Is available through pump manufacturers and distributors or directly from franklin electric at our toll free number 1 800 348 2420.
Caution use subdrive monodrive only with franklin electric 4 inch submersible motors as specified in this manual see table 2 pg.
Red fault code on display fault detected proceed to fault code description and remedy.
Standard pump and franklin electric motor b.
Thank you for your purchase of franklin electric products.
If the subdrive does not give an open phase fault f5 then there is a problem with the subdrive.
In some cases the system will shut itself off until corrective action is taken.
Franklin electric pressure sensor nsf 61 rated provided.
In addition the reduced tank size see table 4 pg.
Connect the subdrive to a dry motor.
The fault light or digital display on the front of the subdrive monodrive controller will flash a given number of times or display a number indicating the nature of the fault.
4 the subdrive monodrive eliminates pressure cycling associated with conventional water well systems and owners of private water well systems can enjoy city like water pressure.
Use of this unit with any other franklin electric motor or with motors from.
If the subdrive does not give an open phase fault 5 fl ashes every 2 seconds then there is a problem with the subdrive.
Connect the subdrive to a dry motor.
If the motor goes through dc test and gives underload fault f1 the subdrive is working properly.